PGA

Portable Gas Analyzer

Simple, reliable, absolute, field portable analyzer for a variety of applications & measurement of various gases

The PGA Portable Gas Analyzer is a battery portable instrument for the intermittent, short-term monitoring of gas concentrations. Single or dual gas versions are available utilizing a highly accurate infra red gas analyzer and/or an electrochemical cell. The instrument can be configured for various gases.

Features

  • Proven IRGA technology with optional electrochemical cell
  • Integral sample pump
  • Battery portable
  • The PGA may be configured to measure the following gases:
    • Methane
    • Oxygen
    • Carbon Monoxide
    • Nitric Oxide
    • Nitrous Oxide
    • Sulphur Dioxide
    • Sulphur Hexafluoride
    • Ammonia
  • Ethane
  • Propane
  • Butane
  • Pentane
  • Hexane
  • Heptane
  • Freons
  • Hydrogen
  • Hydrogen Sulfide
  • The new PGA is the latest addition to the ADC BioScientific range of Geoscience research analyzers. Weighing just 5kg and offering 8 hours of continuous use, the battery operated PGA is set to offer new levels in portability and performance for a field portable gas analyzer.

    Probably the most commonly analyzed gas in related geoscience, environmental science and atmospheric science studies is CO2. The PGA is available in ranges from 0-2000ppm CO2 to 0-100% with a resolution of 0.5% full scale deflection (fsd). This corresponds to10ppm resolution for the 0-2000ppm instrument.

    The PGA suitable for a wide range of experimental studies including elevated CO2 studies, atmospheric CO2 monitoring, FACE experimentation and measuring high concentrations in natural CO2 springs.

  • Measurement technique:

    Non-dispersive infrared absorption with solid state detector.

    Measurement range:

    Up to 100% for gases and saturation concentrations for vapors.

    Resolution:

    0.5% fsd

    Repeatability:

    +/- 1.0% fsd

    Noise:

    0.5% fsd

    Span stability:

    0.5% fsd over 24 hours

    Response time:

    Typically 4 seconds to T90 dependent on cell size.

    Flow rate:

    Typically 0.2 - 1 liter per minute

    Operating temperature range:

    5oC - 40oC

    Battery:

    Rechargeable 3.2Ah lead acid allowing 8 hours of continuous operation.

    Dimensions:

    260 x 80 x 300mm

    Weight:

    5kg

  • PDF document.

  • Enter the information below, and a representative will respond to your request.

    For the full product line, use the Request For Quote page.

    Name required

    Institution required

    Email Required

    Country Required

    Submitting Form...

    The server encountered an error.

    Request sent.

Opti-Sciences, Inc.     8 Winn Avenue      Hudson NH 03051       USA      (603)883-4400

Products

Opti-Sciences, Inc.

8 Winn Ave

Hudson, NH 03051, USA

Phone: (603) 883-4400

Fax: (603) 883-4410